Simulation Project tripleaxis: The source-guide system: Difference between revisions

From E-neutrons wiki
Jump to navigation Jump to search
ucph>Tommy
(Created page with "We use the same cold source as for Simulation project: A powder diffractometer<!--project~\ref{prob:...")
 
m (1 revision imported)
 
(No difference)

Latest revision as of 22:15, 18 February 2020

We use the same cold source as for Simulation project: A powder diffractometer. The opening we are using for the RITA-2 beam port is 0.120 m high and 0.030 m wide.

The RITA-2 guide system starts 1.5 m from the source. It has a 4.5 m long straight section, followed by a 20 m curved section made from 40 0.5 m straight pieces, placed so that the radius-of-curvature is 2408 m. This eliminates the line-of-sight, so to avoid neutrons with very small wavelengths. However, in this assignment we make the simplification that the guide is straight and is in one piece.

The guide material has \(m=2\) and same parameters as in Simulation project: A powder diffractometer. The guide has height 0.120 m and width 0.030 m along its whole length.

Simulate the neutron beam intensity at the exit of the guide for neutrons in the range 0.5 Å - 20 Å.